Os motores de busca de Datasheet de Componentes eletrônicos
Selected language  

  Portuguese  ▼

nome da peças
         descrição  


EQY-6-24 Datasheet(Folha de dados) 3 Page - Mini-Circuits

Nome de Peças. EQY-6-24
descrição  Gain Equalizer
Download  5 Pages
Scroll/Zoom Zoom In 100% Zoom Out
Fbricantes  MINI [Mini-Circuits]
Página de início  http://www.minicircuits.com
Logo 

   
 3 page
background image
Gain Equalizer
Page 3 of 5
Notes
A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.
B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions.
C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled
to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp
Mini-Circuits®
www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com
EQY-6-24+
1. Measured on Mini-Circuits Characterization Test Board TB-EQY-6-24+. See Characterization Test Circuit (Fig. 1)
MCL
EW6
black body
model family designation
index over pad 1
Electrical Specifications1 at 25°C, 50Ω, unless otherwise noted.
Parameter
Condition (GHz)
Min.
Typ.
Max.
Units
Frequency Range
DC
20
GHz
Insertion Loss
0.01
6.5
6.8
7.1
dB
5
6.0
10
3.8
18
0.6
0.9
1.2
20
0.5
VSWR
0.01 -5
1.11
:1
5 - 10
1.22
10 - 18
1.31
18 - 20
1.16
Fig 1. Block Diagram of Test Circuit used for characterization. Test Board TB-EQY-6-24+
Conditions: Attenuation & Return Loss Pin=0 dBm
Characterization Test Circuit
Product Marking
Marking may contain other features or characters for internal lot control
Operating Case Temperature
-55°C to 105°C
Storage Temperature
-65°C to 150°C
RF Input Power3
31 dBm
Absolute Maximum Ratings2
2. Permanent damage may occur if any of these limits are exceeded.
3. Derates linearly to 29 dBm at 105°C
4
1
2
3
5
8
7
6
RF-IN
RF-OUT
DUT




Html Pages

1  2  3  4  5 


Datasheet Download




Ligação URL

ALLDATASHEET é util para você?  [ DONATE ]  

Sobre Alldatasheet   |  Publicidade   |   Contato conosco    |   Política de Privacidade   |   Favoritos   |  Troca de Link    |  Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  , Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp  |   Russian : Alldatasheetru.com
Korean : Alldatasheet.co.kr   |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com  |   Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl