12 / 70 page Overview III-2 Slave Controller – ET1200 Hardware Description 1.1 Frame processing order The ET1200 supports two ports (logical ports 0 and 1) or three ports (logical ports 0, 1, and 3). The frame processing order of the ET1200 depends on the number of ports (logical port numbers are used): Table 2: Frame Processing Order Number of Ports Frame processing order 2 0 →EtherCAT Processing Unit→1 / 1→0 3 0 →EtherCAT Processing Unit→3 / 3→1 / 1→0 Figure 2 shows the frame processing in general: 1 Port 1 Port 3 Auto- Forwarder Port 0 EtherCAT Processing Unit Loopback function ET1200 port 3 open port 3 closed Figure 2: Frame Processing |
Nº de peça semelhante - ET1200 |
|
Descrição semelhante - ET1200 |
|
|
Ligação URL |
Privacy Policy |
ALLDATASHEETPT.COM |
ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |