Os motores de busca de Datasheet de Componentes eletrônicos |
|
ADM1020AR-REEL Folha de dados(PDF) 10 Page - Analog Devices |
|
ADM1020AR-REEL Folha de dados(HTML) 10 Page - Analog Devices |
10 / 12 page REV. 0 ADM1020 –10– ALERT OUTPUT The ALERT output goes low whenever an out-of limit measure- ment is detected, or if the remote temperature sensor is open- circuit. It is an open-drain and requires a 10 k Ω pull-up to V DD. Several ALERT outputs can be wire-ANDED together, so that the common line will go low if one or more of the ALERT out- puts goes low. The ALERT output can be used as an interrupt signal to a processor, or it may be used as an SMBALERT. Slave devices on the SMBus can not normally signal to the master that they want to talk, but the SMBALERT function allows them to do so. One or more ALERT outputs are connected to a common SMBALERT line connected to the master. When the SMBALERT line is pulled low by one of the devices, the following procedure occurs as illustrated in Figure 13. MASTER RECEIVES SMBALERT START ALERT RESPONSE ADDRESS RD ACK DEVICE ADDRESS NO ACK STOP DEVICE SENDS ITS ADDRESS MASTER SENDS ARA AND READ COMMAND Figure 13 Use of SMBALERT 1. SMBALERT pulled low. 2. Master initiates a read operation and sends the Alert Re- sponse Address (ARA = 0001 100). This is a general call address that must not be used as a specific device address. 3. The device whose ALERT output is low responds to the Alert Response Address and the master reads its device ad- dress. The address of the device is now known and it can be interrogated in the usual way. 4. If more than one device’s ALERT output is low, the one with the lowest device address will have priority, in accordance with normal SMBus arbitration. 5. Once the ADM1020 has responded to the Alert Response Address, it will reset its ALERT output, provided that the error condition that caused the ALERT no longer exists. If the SMBALERT line remains low, the master will send ARA again, and so on until all devices whose ALERT outputs were low have responded. LOW POWER STANDBY MODES The ADM1020 can be put into a low power standby mode by setting Bit 6 of the Configuration Register. With Bit 6 low the ADM1020 operates normally. When Bit 6 is high, the ADC is inhibited, any conversion in progress is terminated without writing the result to the corresponding value register. The SMBus is still enabled. Power consumption in the standby mode is reduced to less than 10 µA if there is no SMBus activ- ity, or 100 µA if there are clock and data signals on the bus. When Bit 6 is set , a one-shot conversion of both channels can be initiated by writing XXh to the One-Shot Register (address 0Fh). SENSOR FAULT DETECTION The ADM1020 has a fault detector at the D+ input that detects if the external sensor diode is open-circuit. This is a simple voltage comparator that trips if the voltage at D+ exceeds VCC – 1 V (typical). The output of this comparator is checked when a conversion is initiated, and sets Bit 2 of the Status Reg- ister if a fault is detected. If the remote sensor voltage falls below the normal measuring range, for example due to the diode being short-circuited, the ADC will output –128 (1000 0000). Since the normal operating temperature range of the device only extends down to –55 °C, this output code should never be seen in normal operation, so it can be interpreted as a fault condition. Since it will be outside the power-on default low temperature limit (–55 °C) and any low limit that would normally be programmed, a short-circuit sensor will cause an SMBus alert. In this respect the ADM1020 differs from and improves upon, competitive devices that output zero if the external sensor goes short-circuit. These devices can misinterpret a genuine 0 °C measurement as a fault condition. If the external diode channel is not being used and it is shorted out, the resulting ALERT may be cleared by writing 80h (–128 °C) to the low limit register. APPLICATIONS INFORMATION FACTORS AFFECTING ACCURACY Remote Sensing Diode The ADM1020 is designed to work with substrate transistors built into processors, or with discrete transistors. Substrate transistors will generally be PNP types with the collector con- nected to the substrate. Discrete types can be either PNP or NPN, connected as a diode (base shorted to collector). If an NPN transistor is used then the collector and base are connected to D+ and the emitter to D–. If a PNP transistor is used then the collector and base are connected to D– and the emitter to D+. The user has no choice in the case of substrate transistors but if a discrete transistor is used the best accuracy will be obtained by choosing devices according to the following criteria: 1. Base-emitter voltage greater than 0.25 V at 6 µA, at the high- est operating temperature. 2. Base-emitter voltage less than 0.95 V at 100 µA, at the lowest operating temperature. 3. Base resistance less than 100 Ω. 4. Small variation in hFE (say 50 to 150) which indicates tight control of VBE characteristics. Transistors such as 2N3904, 2N3906 or equivalents in SOT-23 package are suitable devices to use. |
Nº de peça semelhante - ADM1020AR-REEL |
|
Descrição semelhante - ADM1020AR-REEL |
|
|
Ligação URL |
Privacy Policy |
ALLDATASHEETPT.COM |
ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |