Os motores de busca de Datasheet de Componentes eletrônicos |
|
M02-04-01 Folha de dados(PDF) 2 Page - Gamewell-FCI by Honeywell |
|
M02-04-01 Folha de dados(HTML) 2 Page - Gamewell-FCI by Honeywell |
2 / 2 page GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60708 Rev. C page 2 of 2 www.gamewell-fci.com • • Specifications Physical Specifications Base Diameter: 6.875” (17.46 cm) installed in a B200S base Base Height: 3.46” (8.79 cm) installed in B200S base Shipping Weight: 4.6 oz Color: Ivory Material: Bayblend FR110 Operating Temperature Range: 32° F to 100° F (0° C to 38° C) Operating Humidity Range: 15 to 90% relative humidity (non-condensing) Air Velocity: 0 to 4,000 ft/min (0 to 20 m/sec) Electrical Specifications Operating Voltage Range: 15 to 32 VDC Maximum Standby Current: 300 µA at 24 VDC (no communica- tion every 5 seconds with LED blink enabled). Maximum Alarm Current (LED on): 7.2 mA at 24 VDC Sensitivity Settings & Suggested Applications Level 1: 1% per foot (30.48 cm) of smoke. Very clean environments: Used in Laboratories. Level 2: 2% per foot (30.48 cm) of smoke. Clean environments: Used in offices. Level 3: 3% per foot (30.48 cm) of smoke. Moderately clean environments: Used in hotel rooms, dorm rooms. Level 4: 3% per foot (30.48 cm) of smoke with different algorithm processing and weighting of sensor elements. Used in hotel rooms near a shower, boiler rooms. Level 5: 4% per foot (30.48 cm) of smoke. Used in equipment rooms, kitchens, paint shop. Level 6: Thermal alarm at 135° F (57° C). Warning: After the CO cell has reached the end-of-life, the CO sensor no longer provides life safety protection. How- ever, when the fire detector enters Photo, Thermal, Infra- red (PTIR) mode, the following sensitivities apply: Level 1: 1% per foot (30.48 cm) of smoke. Very clean environments: Used in Laboratories. Level 2: 2% per foot (30.48 cm) of smoke. Clean environments: Used in offices. Level 5: 3% per foot (30.48 cm) of smoke. Moderately clean environments: Used in hotel rooms, dorm rooms. Level 6: Thermal alarm at 135° F (57° C). Specifications (Continued) CO Monitoring UL Standard Reference - Alarm Thresholds are as follows: Parts per Million 70 ± 5ppm 150±5ppm 400± 10ppm Detector Response Time, min. 60-240 10-50 4-15 Note: Per UL Standard 2075, the MCS-COF has been tested to the sensitivity limits defined in UL Standard 2034. Ordering Information Part Number Description MCS-COF Advanced Multi-Criteria Fire/CO Detector Note: Due to the unique nature of this detector, please consult your Fire Alarm Control Panel Manufacturer for the specific model and compatibility. Accessories: B200S Addressable Sounder Base M02-04-01 Detector Test Magnet M02-09-01 Telescoping Test Magnet |
Nº de peça semelhante - M02-04-01 |
|
Descrição semelhante - M02-04-01 |
|
|
Ligação URL |
Privacy Policy |
ALLDATASHEETPT.COM |
ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |