Os motores de busca de Datasheet de Componentes eletrônicos
  Portuguese  ▼

Delete All
ON OFF
ALLDATASHEETPT.COM

X  

Preview PDF Download HTML

ZP07-MP503 Folha de dados(PDF) 3 Page - Zhengzhou Winsen Electronics Technology Co., Ltd.

Nome de Peças ZP07-MP503
Descrição Electrónicos  Air-Quality Detection Module
Download  5 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrônico  WINSEN [Zhengzhou Winsen Electronics Technology Co., Ltd.]
Página de início  https://www.winsen-sensor.com/
Logo WINSEN - Zhengzhou Winsen Electronics Technology Co., Ltd.

ZP07-MP503 Folha de dados(HTML) 3 Page - Zhengzhou Winsen Electronics Technology Co., Ltd.

  ZP07-MP503 Datasheet HTML 1Page - Zhengzhou Winsen Electronics Technology Co., Ltd. ZP07-MP503 Datasheet HTML 2Page - Zhengzhou Winsen Electronics Technology Co., Ltd. ZP07-MP503 Datasheet HTML 3Page - Zhengzhou Winsen Electronics Technology Co., Ltd. ZP07-MP503 Datasheet HTML 4Page - Zhengzhou Winsen Electronics Technology Co., Ltd. ZP07-MP503 Datasheet HTML 5Page - Zhengzhou Winsen Electronics Technology Co., Ltd.  
Zoom Inzoom in Zoom Outzoom out
 3 / 5 page
background image
Air-Quality Detection Module
ZP07 Air-Quality Detection Module
Product Description
ZP07 air-quality module adopts flat surface semiconductor
gas sensor. The module has good sensitivity to volatile
organic gases such as formaldehyde, benzene, carbon
monoxide, ammonia, hydrogen, alcohol and smoke of
cigarette, essence &etc. The module has been aging,
debugged, adjusted and calibrated. So it has good
consistency and high sensitivity.
Features
High sensitivity
Low power consumption, long life
Calibrated before shipment
10 seconds to 3 minutes with auto-preheating function
Faulty auto-check, High cost-effective
Application
Air cleaner, fresh-air system, intelligent integrated ceiling, air quality detector, ventilator, air-condition.
Technical Index
Table 1
Picture 1:Module structure diagram
Model No.
ZP07
Detection Gas
formaldehyde, benzene,
carbon monoxide, hydrogen,
alcohol, ammonia, smoke of
cigarette, essence &etc.
Physical Interface
XH2.54-4P terminal sockets
Output Data
0-3 grade pollution signal
Working Voltage
5.0±0.2V DC (No voltage
reverse connect protection)
Output
TTL level (200ohm protected
resistance inside)
Working Current
≤60mA
Warm-up Time
≤3 min
Response Time
≤20s
Recovery Time
≤60s
Operating Temperature
0~50℃
Operating Humidity
≤95%RH
Storage Temperature
20~60℃
Storage Humidity
≤60%RH
Size
24×20×16mm(L×W×H)
Weight
≤ 20g
Sensitivity Attenuator
≤1%/year
Life Span
≥5 years


Html Pages

1  2  3  4  5 


Folha de dados Download

Go To PDF Page


Ligação URL




Privacy Policy
ALLDATASHEETPT.COM
ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn