5.0
6.0
3.0
1.0
2.0
4.0
0
20
40
60
80
AMBIENT TEMPERATURE [˚C]
Max. Load Current vs. Temp.
G E N E R A L SPE C I F I C A T ION S
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc
109 Ohm
Max. Capacitance Input/Output
10 pF
Ambient Operating Temperature Range
-30 to 80ºC
Ambient Storage Temperature Range
-30 to 125ºC
M E C HANI C A L SPE C I F I C A T ION S
Weight: (typical)
0.4 oz. (11g)
Encapsulation:
Thermally Conductive Epoxy
FastFax Document No.107
SERIES CX.
Rev. 012402
PAGE 2 OF 2
C U RR E N T D E R A T IN G C U R V E
Series CX
5Amp • 120/240, 380, 480 Vac • AC Output SIP
©2001 CRYDOM CORP, Specifications subject to change without notice.
AVAILABLE OPTIONS
R
Random Turn-On Switching
Example: CX240D5 R, CX240A5 R
APPROVALS
UL
E116949
CSA
LR81689
VDE 70938
UG (240V, 380V, DC Control Only)
All dimensions are in inches (millimeters)
1.00
MAX.
(25.4)
.700
(17.8)
1.100
(27.9)
1.70
(43.1)
.050
TYP.
(1.3)
CONTROL
LOAD
.300 (7.6)
.100
(2.5)
.040 (1.0) DIA.
(4 PLACES)
.200
(5.1)
.300 TYP.
(7.6)
43
2
1
AC CONTROL
PIN 1: AC LOAD
PIN 2: AC LOAD
PIN 3: AC CONTROL
PIN 4: AC CONTROL
DC CONTROL
PIN 1: AC LOAD
PIN 2: AC LOAD
PIN 3: +DC CONTROL
PIN 4: -DC CONTROL
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506