5 / 6 page 5 Specifications Input and output RF input/output DUT RF IN/OUT (N1961A front) Maximum input: 4 W CW, 0 VDC Maximum output: Typically +15 dBm, Input impedance: 50 Ohm nominal CAL RF OUT (N1961A front) Maximum output: +15 dBm Maximum reverse power: 1 W CW, 0 VDC Nominal impedance: 50 Ohm External reference input EXT REF IN (Located at rear panel of the rack) Input frequency: 10 MHz (±5 ppm) Input level range: 0 to +13 dBm Input impedance: 50 Ohm nominal PC/peripheral input/output USB Four auxiliary ports are available: one on the front I/O panel, two on the front panel, and one on the rear panel of the industrial PC Serial (RS-232) Two on the front I/O panel, DB9 male connector LAN One on the front I/O panel, one on the real I/O panel (for intra/internet connection) 100 Base-T Ethernet, RJ-45 connector GPIB One on the front I/O panel for additional instrument connection Timebase specification Internal timebase Internal timebase of the 8960/E5515C wireless communications test set is fed to all other instruments in the system. The 8960’s internal oven- controlled crystal oscillator’s specifications are as follows: • Aging rates: < ±0.1 ppm per year, < ±0.005 ppm peak-to-peak per day during any 24-hour period starting 24 hours or more after a cold start • Temperature stability: < ±0.01 ppm, frequency variation from +25 °C over the temperature range 0 to +55 °C Warm-up time: 5 minutes to be within ±0.1 ppm of frequency at one hour, 15 minutes to be within ±0.01 ppm of frequency at one hour External timebase When the external reference signal is present on the EXT REF IN, the system instruments will be locked to it Recommended system path loss calibration interval Nominal One year Exception System path loss calibration must be performed when any of the following events occur in the related signal path: • Any instrument RF interconnect cable is replaced • Any instrument is calibrated Any instrument is repaired and re-calibrated General specifications Operating conditions General Indoor Storage temperature –20 to +70 °C Operating temperature +10 to +30 °C Accuracy specified temperature +20 to +30 °C (Refer to measurement accuracy specification of individual radio technology for further information) Humidity (relative) 5 to 80% relative humidity (non-condensing) Altitude 0 to 2 km Power requirement 90 to 254 VAC, 50 to 60 Hz, 4118 VA maximum Rack dimensions 1.6 m rack (EIA: 32 RU) Two/three racks configuration (H x W x D) 1620 mm x 1200 mm x 905 mm (63.8 in x 47.2 in x 35.6 in) When mounting work surfaces, maximum extra-depth is 500 mm (19.7 in) Weight 1.6 m rack x 2 racks 1.6 m rack x 3 racks 505 kg maximum (1,110 lbs) 714 kg maximum (1,570.8 lbs) |
Nº de peça semelhante - GS-8830 |
|
Descrição semelhante - GS-8830 |
|
|
Ligação URL |
Privacy Policy |
ALLDATASHEETPT.COM |
ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |