11 / 32 page 11 FN6667.4 February 11, 2010 The I2C bus is deactivated in battery-backup mode to reduce power consumption. Aside from this, all RTC functions are operational during battery-backup mode. Except for SCL and SDA, all the inputs and outputs of the ISL12020M are active during battery-backup mode unless disabled via the control register. The device Time Stamps the switchover from VDD to VBAT and VBAT to VDD, and the time is stored in tSV2B and tSB2V registers respectively. If multiple VDD power-down sequences occur before status is read, the earliest VDD to VBAT power-down time is stored and the most recent VBAT to VDD time is stored. Temperature conversion and compensation can be enabled in battery-backup mode. Bit BTSE in the BETA register controls this operation, as described in “BETA Register (BETA)” on page 19. Power Failure Detection The ISL12020M provides a Real Time Clock Failure Bit (RTCF) to detect total power failure. It allows users to determine if the device has powered up after having lost all power to the device (both VDD and VBAT). Brownout Detection The ISL12020M monitors the VDD level continuously and provides warning if the VDD level drops below prescribed levels. There are six (6) levels that can be selected for the trip level. These values are 85% below popular VDD levels. The LVDD bit in the Status Register will be set to “1” when brownout is detected. Note that the I2C serial bus remains active unless the Battery VTRIP levels are reached. Battery Level Monitor The ISL12020M has a built in warning feature once the Back Up battery level drops first to 85% and then to 75% of the battery’s nominal VBAT level. When the battery voltage drops to between 85% and 75%, the LBAT85 bit is set in the status register. When the level drops below 75%, both LBAT85 and LBAT75 bits are set in the status register. The battery level monitor is not functional in battery backup mode. In order to read the monitor bits after powering up VDD, instigate a battery level measurement, which is set by setting the TSE bit to "1" (BETA register), and then read the bits. There is a Battery Time Stamp Function available. Once the VDD is low enough to enable switchover to the battery, the RTC time/date are written into the TSV2B register. This information can be read from the TSV2B registers to discover the point in time of the VDD power-down. If there are multiple power-down cycles before reading these registers, the first values stored in these registers will be retained. These registers will hold the original power-down value until they are cleared by setting CLRTS = 1 to clear the registers. The normal power switching of the ISL12020M is designed to switch into battery-backup mode only if the VDD power is lost. This will ensure that the device can accept a wide range of backup voltages from many types of sources while reliably switching into backup mode. Note that the ISL12020M is not guaranteed to operate with VBAT < 1.8V. If the battery voltage is expected to drop lower than this minimum, correct operation of the device, especially after a VDD power-down cycle, is not guaranteed. The minimum VBAT to insure SRAM is stable is 1.0V. Below that, the SRAM may be corrupted when VDD power resumes. Real Time Clock Operation The Real Time Clock (RTC) uses an integrated 32.768kHz quartz crystal to maintain an accurate internal representation of second, minute, hour, day of week, date, month, and year. The RTC also has leap-year correction. The clock also corrects for months having fewer than 31 days and has a bit that controls 24-hour or AM/PM format. When the ISL12020M powers up after the loss of both VDD and VBAT, the clock will not begin incrementing until at least one byte is written to the clock register. Single Event and Interrupt The alarm mode is enabled via the MSB bit. Choosing Single Event or interrupt alarm mode is selected via the IM bit. Note that when the frequency output function is enabled, the alarm function is disabled. The standard alarm allows for alarms of time, date, day of the week, month, and year. When a time alarm occurs in single event mode, the IRQ/FOUT pin will be pulled low and the alarm status bit (ALM) will be set to “1”. VBAT - VBATHYS VBAT VBAT + VBATHYS BATTERY-BACKUP MODE V DD VTRIP 2.2V 1.8V FIGURE 12. BATTERY SWITCHOVER WHEN VBAT <VTRIP FIGURE 13. BATTERY SWITCHOVER WHEN VBAT >VTRIP VTRIP VBAT VTRIP + VTRIPHYS BATTERY-BACKUP MODE VDD VTRIP 3.0V 2.2V ISL12020M |
Nº de peça semelhante - ISL12020M |
|
Descrição semelhante - ISL12020M |
|
|
Ligação URL |
Privacy Policy |
ALLDATASHEETPT.COM |
ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |