Os motores de busca de Datasheet de Componentes eletrônicos |
|
AMC1200BDUBR Folha de dados(PDF) 3 Page - Texas Instruments |
|
|
AMC1200BDUBR Folha de dados(HTML) 3 Page - Texas Instruments |
3 / 24 page AMC1200 AMC1200B www.ti.com SBAS542B – APRIL 2011 – REVISED AUGUST 2012 IEC 60747-5-2 INSULATION CHARACTERISTICS Over operating free-air temperature range (unless otherwise noted). PARAMETER TEST CONDITIONS VALUE UNIT VIORM Maximum working insulation voltage 1200 VPEAK Qualification test: after Input/Output Safety Test Subgroup 1140 VPEAK 2/3 VPR = VIORM x 1.2, t = 10 s, partial discharge < 5 pC Qualification test: method a, after environmental tests VPR Input to output test voltage subgroup 1, VPR = VIORM x 1.6, t = 10 s, partial discharge 1920 VPEAK < 5 pC 100% production test: method b1, VPR = VIORM x 1.875, 2250 VPEAK t = 1 s, partial discharge < 5 pC AMC1200 4000 VPEAK VIOTM Transient overvoltage Qualification test: t = 60 s AMC1200B 4250 VPEAK AMC1200 4000 VPEAK Qualification test: VTEST = VISO , t = 60 s AMC1200B 4250 VPEAK VISO Insulation voltage per UL AMC1200 4800 VPEAK 100% production test: VTEST = 1.2 x VISO , t = 1 s AMC1200B 5100 VPEAK RS Insulation resistance VIO = 500 V at TS > 109 Ω PD Pollution degree 2 ° IEC SAFETY LIMITING VALUES Safety limiting intends to prevent potential damage to the isolation barrier upon failure of input or output (I/O) circuitry. A failure of the I/O circuitry can allow low resistance to ground or the supply and, without current limiting, dissipate sufficient power to overheat the die and damage the isolation barrier, potentially leading to secondary system failures. The safety-limiting constraint is the operating virtual junction temperature range specified in the Absolute Maximum Ratings table. The power dissipation and junction-to-air thermal impedance of the device installed in the application hardware determine the junction temperature. The assumed junction-to-air thermal resistance in the Thermal Information table is that of a device installed in the JESD51-3, Low Effective Thermal Conductivity Test Board for Leaded Surface Mount Packages and is conservative. The power is the recommended maximum input voltage times the current. The junction temperature is then the ambient temperature plus the power times the junction-to-air thermal resistance. PARAMETER TEST CONDITIONS MIN TYP MAX UNIT IS Safety input, output, or supply current θJA = 246°C/W, VIN = 5.5 V, TJ = +150°C, TA = +25°C 10 mA TC Maximum case temperature +150 °C IEC 61000-4-5 RATINGS PARAMETER TEST CONDITIONS VALUE UNIT VIOSM Surge immunity 1.2- μs/50-μs voltage surge and 8-μs/20-μs current surge ±6000 V IEC 60664-1 RATINGS PARAMETER TEST CONDITIONS SPECIFICATION Basic isolation group Material group II Rated mains voltage ≤ 150 VRMS I-IV Rated mains voltage ≤ 300 VRMS I-IV Installation classification Rated mains voltage ≤ 400 VRMS I-III Rated mains voltage < 600 VRMS I-III Copyright © 2011–2012, Texas Instruments Incorporated Submit Documentation Feedback 3 Product Folder Links: AMC1200 AMC1200B |
Nº de peça semelhante - AMC1200BDUBR |
|
Descrição semelhante - AMC1200BDUBR |
|
|
Ligação URL |
Privacy Policy |
ALLDATASHEETPT.COM |
ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |