Os motores de busca de Datasheet de Componentes eletrônicos |
|
HCPL-250L-560E Folha de dados(PDF) 6 Page - AVAGO TECHNOLOGIES LIMITED |
|
HCPL-250L-560E Folha de dados(HTML) 6 Page - AVAGO TECHNOLOGIES LIMITED |
6 / 12 page 6 Insulation and Safety Related Specifications 8-Pin DIP (300 Mil) SO-8 Parameter Symbol Value Value Units Conditions Minimum External Air L (101) 7.1 4.9 mm Measured from input terminals to output Gap (External Clearance) terminals, shortest distance through air. Minimum External Tracking L (102) 7.4 4.8 mm Measured from input terminals to output (External Creepage) terminals, shortest distance path along body. Minimum Internal Plastic 0.08 0.08 mm Through insulation distance, conductor to Gap (Internal Clearance) conductor, usually the direct distance between the photoemitter and photodetector inside the optocoupler cavity. Tracking Resistance CTI 200 200 Volts DIN IEC 112/VDE 0303 Part 1 (Comparative Tracking Index) Isolation Group IIIa IIIa Material Group (DIN VDE 0110, 1/89, Table 1) IEC/EN/DIN EN 60747-5-2Insulation Related Characteristics Description Symbol PDIP Option 060 SO-8 Option 60 Units Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 150 V rms I-IV for rated mains voltage ≤ 300 V rms I-IV I-III for rated mains voltage ≤ 600 V rms I-III I-II Climatic Classification 55/85/21 55/85/21 Pollution Degree (DIN VDE 0110/1.89) 2 2 Maximum Working Insulation Voltage VIORM 630 566 Vpeak Input to Output Test Voltage, Method b* VIORM x 1.875 = VPR, 100% Production Test VPR 1181 1063 Vpeak with tm = 1 sec, Partial Discharge < 5 pC Input to Output Test Voltage, Method a* VIORM x 1.5 = VPR, Type and Sample Test, VPR 945 849 Vpeak tm = 60 sec, Partial Discharge < 5 pC Highest Allowable Overvoltage* VIOTM 6000 4000 Vpeak (Transient Overvoltage, tini = 10 sec) Safety Limiting Values (Maximum values allowed in the event of a failure, also see Figure 16, Thermal Derating curve.) Case Temperature TS 175 150 ˚C Input Current IS,INPUT 230 150 mA Output Power PS,OUTPUT 600 600 mW Insulation Resistance at TS, VIO = 500 V RS ≥ 109 ≥ 109 Ω *Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a detailed description. Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica- tion. |
Nº de peça semelhante - HCPL-250L-560E |
|
Descrição semelhante - HCPL-250L-560E |
|
|
Ligação URL |
Privacy Policy |
ALLDATASHEETPT.COM |
ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |