TS7001 Folha de dados(PDF) 9 Page - Silicon Laboratories |
|
TS7001 Folha de dados(HTML) 9 Page - Silicon Laboratories |
9 / 21 page TS7001 TS7001 Rev. 1.0 Page 9 TS7001 CONTROL REGISTER DESCRIPTION The TS7001’s write-only control register is 8-bits wide. Serial ADC configuration data is uploaded from the host processor at the TS7001’s DIN pin on low-to-high SCLK transitions. Serial input data is uploaded to the TS7001 simultaneously as the conversion result is transferred out of the TS7001. All serial data transfers require 16 serial clocks transitions. After a high-to-low CS transition signal, serial data available on the first eight low-to-high SCLK transitions is transferred into the control register. The first bit in the serial data stream is always interpreted as the MSB. Upon initial power- up, the TS7001’s default control register bit is cleared to all zeros (all “0”s). Table 1 lists the functions of the Control Register’s 8 bits. Table 1. TS7001’s 8-Bit Control Register Content Description DB7 (MSB) DB6 DB5 DB4 DB3 DB2 DB1 DB0 (LSB) DONTC ZERO REF SIN/DUAL CH ZERO PM1 PM0 DBx Label Comment 7 DONTC Control Register DB7: Bit status of DB7 is “Don’t Care.” In other words, the DB7 bit can be a “0” or a “1”. 6 ZERO Control Register DB6: To ensure correct TS7887 operation, Control Register DB6 status must always be a “zero” (“0”). 5 REF Control Register DB5 – Internal Voltage Reference Configuration: The status of DB5 determines whether the TS7001’s internal voltage reference is enabled or disabled. A “0” in the DB5 location will enable the TS7001’s internal voltage reference (default condition). To disable the TS7001’s internal voltage reference, a “1” must be written into DB5’s register location. 4 SIN/DUAL Control Register DB4 - Single-Channel/Dual-Channel Configuration. Control Register DB4 configures the TS7001 as a single-channel or two-channel ADC. Loading a “zero” (“0”) into this register location configures the TS7001 for single-channel operation with the AIN1/VREF pin configured to for internal VREF operation (default configuration). In this case, the analog input signal range is 0V to VREF. Loading a “one” (“1”) into this register location configures the TS7001 for two-channel operation with the AIN1/VREF pin configured to its AIN1 function as the second analog input. In addition, the conversion process’s reference voltage is internally connected to VDD. In this case, the analog input signal range is 0V to VDD. To obtain best performance from the TS7001 in two-channel operation, the ADC’s internal reference should be disabled; that is, a “1” should be loaded into DB5’s register location. 3 CH Control Register DB3 - Channel Select Bit: The bit status of DB3 determines on which channel the TS7001 is converting. When the ADC is configured for dual-channel operation, DB3 determines which channel is converted on the next conversion cycle. When DB3 is a “zero” (a “0”), the AIN0 input is selected and, when DB3 is a “one” (a “1”), the AIN1 input is selected. DB3 should be a “zero” (“0”) when the TS7001 is configured for single-channel operation. 2 ZERO Control Register DB2: To ensure correct TS7887 operation, Control Register DB2 status must always be a “zero” (“0”). 1 PM1 Control Register DB1 and DB0 - Power Management Operating Modes: DB1 and DB0 are decoded to configure the TS7001 into one of four operating modes as shown in Table 2. 0 PM0 Table 2. TS7001’s Power Management Operating Modes PM1 PM0 Mode 0 0 PM Mode 1: In this operating mode, the TS7001’s power-down mode is enabled if its CS input is a “one” ( a “1”) and is operating in full-power mode when its CS input is a “zero” (a “0”). Thus, the TS7001 is powered down on a low-to-high CS transition and is powered up on a high-to-low CS transition. 0 1 PM Mode 2: In this operating mode and regardless of the status of any of the logic inputs, the TS7001 is always fully powered up. 1 0 PM Mode 3: In this operating mode, the TS7001 is automatically powered down at the end of each conversion regardless of the state of the CS input. ADC wake-up time from full shutdown is 5 μs and system design should ensure that at least 5 μs have elapsed before attempting to perform a conversion in this mode; otherwise, an invalid conversion result may occur. 1 1 PM Mode 4: In this operating mode, the TS7001 is configured for standby operation after conversion. Sections of the TS7001 are powered down; however, the internal 2.5-V reference voltage remains powered up. While PM Mode 4 is similar to PM Mode 3, PM Mode 4 operation allows the TS7001 to power up much faster. For optimal performance, the Control Register’s REF bit (DB5) should be a “zero” (“0”) to ensure the internal reference is enabled/remains enabled. |
Nº de peça semelhante - TS7001 |
|
Descrição semelhante - TS7001 |
|
|
Ligação URL |
Privacy Policy |
ALLDATASHEETPT.COM |
ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |