Os motores de busca de Datasheet de Componentes eletrônicos |
|
ESX10-TB-14DC24V-1A-E Folha de dados(PDF) 1 Page - ETAL Group |
|
ESX10-TB-14DC24V-1A-E Folha de dados(HTML) 1 Page - ETAL Group |
1 / 14 page www.e-t-a.de Electronic Circuit Protector ESX10-T.-DC 24 V 1642 1 4 Description Technical data (Tambient = 25 °C, operating voltage US = DC 24 V) ESX10-TD Electronic circuit protector type ESX10-T is designed to ensure selective disconnection of DC 24 V load systems. DC 24 V power supplies, which are widely used in industry today, will shut down the output in the event of an overload with the result that one faulty load in the system can lead to complete disconnection of all loads. As well as an unidentified failure this also means stoppage of the whole system. Through selective disconnection the ESX10-T responds much faster to overload or short circuit conditions than the switch-mode power supply. This is achieved by active current limitation. The ESX10-T limits the highest possible current to 1.3 to 1.8 times the selected rated current of the circuit protector. Thus it is possible to switch on capacitive loads of up to 75,000 µF, but they are disconnected only in the event of an overload or short circuit. For optimal alignment with the characteristics of the application the current rating of the ESX10-T can be selected in fixed values from 0.5 A...12 A or in adjustable ratings e.g. [2 A/4 A/6 A]. Failure and status indication are provided by a multicolour LED and an integral short- circuit-proof status output or a potential-free signal contact. Remote operation is possible by means of a remote reset signal or a remote ON/OFF control signal. The manual ON/OFF button allows separate actuation of individual load circuits. The ESX10-T, with a width of only 12.5 mm, can be snapped onto symmetrical rails ensuring ease of installation and saving space in control cabinets. Upon detection of overload or short circuit in the load circuit, the MOSFET of the load output will be blocked to interrupt the current flow. The load circuit can be re-activated via the remote electronic reset input, control input or manually by means of the ON/OFF button. US patent number: US 6,490,141 B2 US patent number: US 8,237,311 B2 Features l Selective load protection, electronic trip characteristics. l Suitable for all kinds of loads (DC 24 V motors upon request) l Active current limitation for safe connection of capacitive loads up to 75,000 µF and on overload/short circuit. l ESX10-TA/-TB: Current ratings 0.5 A...12 A ESX10-TD: adjustable ratings [0.5 A/1 A/2 A], [2 A/3 A/4 A], [2 A/4 A/6 A] and [6 A/8 A/10 A] l Reliable overload disconnection with 1.1 x IN plus, even with long load lines or small cable cross sections (see table 3). l Manual ON/OFF button (S1). l Control input IN+ for remote ON/OFF signal (option). l Electronic reset input RE (option). l Clear status and failure indication through LED, status output SF or Si contact F. l Integral fail-safe element adjusted to current rating. l Width per unit only 12.5 mm. l Rail mounting l Ease of wiring through busbar LINE+ and 0 V as well as signal bars and bridges. l Additional versions with ATEX approval available. Marking: II 3G Ex nA IIB T4 Gc X ESX10-TA-...- E and ESX10-TB-...E Please observe separate operating instructions: Operating data Operating voltage US DC 24 V (18...32 V) Current rating IN fixed current ratings: Type ESX10-TA-... and -TB-...: 0.5, 1 A, 2 A, 3 A, 4 A, 6 A, 8 A, 10 A, 12 A adjustable ratings: Type ESX10-TD-...: [0.5 A/1 A/2 A], [2 A/4 A/6 A], [6 A/8 A/10 A] Type ESX10-TD-101-...: [2 A/3 A/4 A] Closed current I0 ON condition: typically 20...30 mA depending on signal output Status indication l multicolour LED: by means of Green: - unit is ON, power-MOSFET is switched on - status output SF ON, supplies + DC 24 V Orange: - in the event of overload or short circuit until electronic disconnection Red: - unit electronically disconnected - load circuit/Power-MOSFET OFF OFF: - manually switched off (S1 = OFF) or device is dead - undervoltage (US < 8 V) - after switch-on till the end of the delay period l status output SF (option) l potential-free signal contact F (option) l ON/OFF/ condition of switch S1 Load circuit Load output Power-MOSFET switching output (high side switch) Overload disconnection typically 1.1 x IN (1.05...1.35 x IN) Short-circuit current IK Active current limitation with ILimit = typically 1.8/1.5/1.4/4.3 x IN, ILimit depending on IN (typical ILimit - values see table 1) Trip characteristic active current limitation (see table 1) Trip thresholds/trip times 1. threshold: (t1, t2) at overcurrent at Iload> typically 1.1 x IN...ILimit: (ILimit see table 1) t1 = typically 3s. 2. threshold: at Iload = ILimit: t2 = typically 100 ms...3 s. Temperature disconnection internal temperature monitoring with electronic disconnection Low voltage monitoring load output with hysteresis, no reset required load “OFF” at US < 8 V |
Nº de peça semelhante - ESX10-TB-14DC24V-1A-E |
|
Descrição semelhante - ESX10-TB-14DC24V-1A-E |
|
|
Ligação URL |
Privacy Policy |
ALLDATASHEETPT.COM |
ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |