2 / 14 page Electronic Circuit Protector ESX10-T.-DC 24 V www.e-t-a.de Electronic Circuit Protector ESX10-T.-DC 24 V 1642 2 4 Starting delay tstart typically 0.5 sec after every switch-on and after applying US Disconnection of load circuit electronic disconnection Free-wheeling circuit external free-wheeling diode recommended with inductive load Several load outputs must not be connected in parallel Status output SF ESX10-T.-114/-124/ Electrical data plus-switching signal output, connects US to terminal 12 of module 17plus nominal data: DC 24 V / max. 0.2 A (short circuit proof) status output is internally connected to GND with a 10 kOhm resistor Status OUT ESX10-TB-114/-124 (signal status OUT), at US = +24 V +24 V = S1 is ON, load output connected through 0V = S1 is ON, load output blocked and/or switch S1 is OFF red LED lighted OFF condition 0 V level at status output when: l switch S1 is in ON position, but device is still in switch-on delay l switch S1 is OFF, or control signal OFF, device is switched off l no operating voltage US Signal output F ESX10-T.-101/-102 Electrical data potential-free signal contact max. DC 30 V/0.5 A, min. 10 V/10 mA ON condition LED green voltage US applied, switch S1 is in ON position no overload, no short circuit OFF condition LED off l device switched off (switch S1 is in OFF position) l no voltage US applied Fault condition LED orange overload condition > 1.1 x IN up to electronic disconnection Fault condition LED red electronic disconnection upon overload or short circuit ESX10-TB-101 single signal, make contact contact SC/SO-SI open ESX10-TB-102 single signal, break contact contact SC/SO-SI closed Fault signal output fault conditions: l no operating voltage US l ON/OFF switch S1 is in OFF position l red LED lighted (electronic disconnection) Reset input RE ESX10-T.-124/-127 Electrical data voltage: max. + DC 32 V high > DC 8 V ≤ DC 32 V low ≤ DC 3 V > 0 V power consumption typically 2.6 mA (+DC 24 V) min. pulse duration typically 10 ms Reset signal RE The electronically blocked (terminal 22) ESX10-TB-124/-127 may remotely be reset via an external momentary switch due to the falling edge of a +24 V pulse. A common reset signal can be applied to several devices simultaneously. Switched on devices remain unaffected. Control input IN+ ESX10-T.-114 Electrical data see reset input RE Control signal IN+ +24V level (HIGH): device will be switched (terminal 21) on by a remote ON/OFF signal 0 V level (LOW): device will be switched off by a remote ON/OFF signal Switch S1 ON/OFF unit can only be switched on with S1 if a HIGH level is applied to IN+ Technical data (Tambient = 25°C, operating voltage US = DC 24 V) Technical data (Tambient = 25°C, operating voltage US = DC 24 V) LED display ON: LED green OFF: LED red General data Fail-safe element: backup fuse for ESX10-T not required because of the integral redundant fail-safe element Terminals LINE+ / LOAD+ / 0V screw terminals M4 max. cable cross section flexible with wire end ferrule w/wo plastic sleeve 0.5 – 10 mm2 wire stripping length 10 mm tightening torque (EN 60934) 1.5 – 1.8 Nm multi-lead connection (2 identical cables) rigid/flexible 0.5 – 4 mm2 flexible with wire end ferrule without plastic sleeve 0.5 – 2,5 mm2 flexible with TWIN wire end ferrule with plastic sleeve 0.5 – 6 mm2 Terminals aux. contacts screw terminals M3 max. cable cross section flexible with wire end ferrule w/wo plastic sleeve 0.25 – 2.5 mm2 wire stripping length 8 mm tightening torque (EN 60934) 0.5 – 0.6 Nm Housing material moulded Mounting symmetrical rail to EN 50022-35x7.5 Ambient temperature -25...+50 °C (without condensation, see EN 60204-1) Storage temperature -40...+70 °C Humidity 96 hrs/95 % RH/40 °C to IEC 60068-2-78, test Cab. climate class 3K3 to EN 60721 Vibration 3 g, test to IEC 60068-2-6 test Fc Degree of protection housing: IP20 EN 60529 terminals: IP20 EN 60529 EMC emission: EN 61000-6-3 (EMC directive, CE logo) susceptibility: EN 61000-6-2 Insulation co-ordination 0.5 kV/2 pollution degree 2 (IEC 60934) re-inforced insulation in operating area dielectric strength max. DC 32 V (load circuit) Insulation resistance (OFF condition) n/a, only electronic disconnection Approvals CE-logo (ESX10-TA/-TB/-TD) UL 2367, File # E306740, Solid State Overcurrent Protectors UL 508, File # E322549 Approvals UL 1604, File # E320024 (class Ι, division 2, (ESX10-TA/-TB) groups A, B, C, D) CSA C22.2 No: 14, File # 16186 CSA C22.2 No: 142, File # 16186 CSA C22.2 No: 213 (class Ι, division 2) Dimensions (W x H x D) 12.5 x 80 x 83 mm Mass approx. 65 g |
Nº de peça semelhante - ESX10-TB-122DC24V-6A-E |
|
Descrição semelhante - ESX10-TB-122DC24V-6A-E |
|
|
Ligação URL |
Privacy Policy |
ALLDATASHEETPT.COM |
ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |